Minutes, IBIS Quality Teleconference July 29, 2003

TIME AND PHONE FOR NEXT MEETING
August 12, 2003
9-10 AM EST (6-7 AM PST)
Phone: 408-974-8478 or 800-249-5618
Meeting access: CONFERENCE SERVER 1, Conference ID: 54644

ROLL CALL
Adam Tambone adamt@maine.rr.com
*Barry Katz bkatz@sisoft.com
Benjamin P Silva benjamin.p.silva@intel.com
*Bob Ross bob@teraspeed.com
Brian Arsenault arsenault_brian@emc.com
*Eckhard Lenski Eckhard.Lenski@siemens.com
Eric Brock ebrock@sisoft.com
Gregory R Edlund gedlund@us.ibm.com
Hazem Hegazy hazem_hegazy@mentorg.com
John Figueroa jfigueroa@apple.com
John Angulo, john_angulo@mentorg.com
Katja Koller Katja.Koller@siemens.com
Kevin Fisher kfisher@sisoft.com
*Kim Helliwell kimgh@apple.com
Lance Wang lwang@cadence.com
*Lynne Green lgreen@cadence.com
Mike Labonte milabont@cisco.com
Peter LaFlamme plaflamm@amcc.com
Robert Haller rhaller@sisoft.com
Roy Leventhal Roy_Leventhal@3com.com
Sherif Hammad sherif_hammad@mentorg.com
*Todd Westerhoff twesterh@cisco.com
Tom Dagostino tom@teraspeed.com
*Kazuyoshi Shoji kshohji@hitachi-ul.co.jp
*Sadahiro Nonoyama nonoyama@hitachi-ul.co.jp

Everyone in attendance marked by  *

Interested, but have not yet attended:
    Ralf Bruening Zuken ralf.bruening@zuken.de

NOTE: "AR" =3D Action Required.

 -----------------------MINUTES ---------------------------

  - Review of minutes for July 15, 2003
   Accepted as written.

  - Announcements
             	EIA Call for Patent Disclosure
   No company disclosed a patent.

  - AR Review
   June 17th minutes uploaded.
   File name updated per minutes of June 17th.

  - Opens for new items
   Bob Ross requested BIRD 82 discussion.  This addresses the clamp
double-counting issue.
   Bob Ross sent Bob Haller some IBIS 4.0 test cases.  Beta parser is
uploaded on IBIS web site.

AR: Lynne Green and Bob Haller to submit revised BIRD 82.
AR: Bob Haller, upload the IBIS test cases.

  - Detailed Documentation review

            Waveform_processing.txt
   Item 13: S_overshoot_*: Typ value required if used, required for
Level 1.
   Item 14: Add "only when D_overshoot_high and D_overshoot_high not
defined."
Might also need another sentence for clarification.
   Item 16: Clarification of static and dynamic limits.  Dynamic applies
over delta-time,
while static applies for all times.  Both limits apply together.
Delta-time starts when
dynamic value crosses static limit.
   Replace "should" with "must" in several places.

            VT_curves.txt
   Require 4 V-t curves for I/O and Output for Level 1, and encouraged
for Level 0.
Open sink/source/drain buffers would have 2 V-t curves.
   If Rload=3DR_fixture and Voltage=3DV_fixture, and all other fixture
elements (*_dut, *_fixture)
are zeroed out, then [Ramp] should match V-t curves.  Parser does not
check this.
   Level 1: Require visual check for "ballpark" consistency between Ramp
and V-t curves.


  - Plans and Schedule for next meeting
   Finish review of VT_curves.txt.

Next meeting:
August 12, 2003
9-10 AM EST (6-7 AM PST)
Phone: 408-974-8478 or 800-249-5618
Meeting access: CONFERENCE SERVER 1, Conference ID: 54644.